Concern: River Hill High School: November 24th, 2020 (CXRHHS2020000198)

Location
Server Room 225
Date of IEQ Report Form
Date of Report
Concern
The restoration contractor uncovered mold growth behind book shelving while addressing a water incident (see IEQ Concern CXRHHS2020000196). The mold growth is from a past incident that was not known about.
IEQ Investigation Process

Identify deficiencies that may impact IEQ and/or sources of odor concerns. Typically includes the following depending on the nature of concern, but not limited to:

  • interview/questionnaire of concern individual(s)
  • inspection above drop ceiling (condition of roof deck, pipe insulation, return air plenum)
  • inspection of ventilation system (operation of variable air volume box and outdoor air dampers, check controls, measurements of carbon dioxide, temperature and relative humidity, sources near outdoor air intake, measure return and supply air volume, cleanliness of coils, liner and condensate pan)
  • inspection of exterior
  • inspection below drop ceiling (housekeeping, sink and floor drain traps, signs of past and present moisture concern via visual and/or moisture meter, mold growth, ensure connection of current and capping of abandoned sanitary vents, odorizers, excessive plants and fabric items, identify potential pathways, and measure volatile organic compounds, carbon monoxide, and lighting)
Findings

Date(s) of Assessment:  November 23, 2020

On November 20, 2020, the restoration contractor addressing a current water release event for the Office of Environment uncovered mold growth behind bookcases removed to address impacted drywall.  The mold growth was from an unknown past event.  The mold growth (~ 40 square feet) was on the drywall and the backing of two bookcases.

 

Corrective Actions
November 23rd, 2020

On November 23, 2020, the Office of Environment assessed the concern with the contractor to determine a plan of action.  The backing of the bookcases were cleaned/disinfected and sealed with an encapsulant paint.  Impacted drywall was removed and replaced with new.  The work was performed under a negative air containment.

Closed
Yes
Tracking Number
CXRHHS2020000198